Customizing the System Status Panel
Customize the System Status panel to display the following status information:
Uncleared Event Status A count that indicates the number of
uncleared event statuses
that are Critical,
Major, Minor, and Normal for any given system collection. Each number is a hyperlink to a detailed
list of events with that particular status. By clicking the number, an event collection appears with those
particular events and their corresponding systems.
Health Status A count that indicates the number of systems, in a given system collection, that have
a
system health status
that is Critical, Major, Minor, and Normal. Each number is a hyperlink to a
detailed list of systems with that particular status. By clicking the number, a system collection appears
with those particular systems. Health status is not shown by default but can be configured to appear.
NOTE: The system health status information displays only when it is customized to display the
system health status.
Alarm An alarm can be customized to appear for specific criteria for any given system collection.
The alarm alerts you that a particular criterion has been met by one or more systems in that collection.
For example, you might receive an alarm that a storage system has a critical uncleared event, or critical
health status. Because the System Status panel is continually updated, the alarm appears until the
event is cleared, the system is removed from the collection, or the alarm customization is changed so
that it no longer applies. If the System Status panel is collapsed, and an alarm occurs, it opens
automatically so that the alarm is visible. You can collapse the panel, but it continues to open as long
as the alarm is relevant. To have the panel remain collapsed, you must clear the offending event or
system status or reconfigure the status display to no longer display alarms.
Legend of status icons To display a list of status icons, click Legend in the System Status panel.
Legend information appears in a separate window and remains open until you close it.
To customize the System Status panel:
1. Click Customize in the upper-right corner of the System Status panel. The Customize System Status
page appears.
2. Select the first Show summary of, and then select uncleared event status or health status.
a. Select the system collection All Systems, or select another system collection from the dropdown
list.
b. Edit the Label if desired.
3. Select the second Show summary of, and then select uncleared event status or health status.
a. Select the system collection All Systems, or select another system collection from the dropdown
list.
b. Edit the Label if desired.
4. Select to Show an alarm when any system meets the condition.
a. Select the Condition.
b. Select the system collection All Systems, or select another system collection from the dropdown
list.
c. Edit the Label if desired.
5. Click OK to save changes.
Note: Clicking Restore Defaults returns the customization screen to its default condition: only the
uncleared event status
appears in the banner. Health status and the alarm are disabled. All personalized
information is removed.