HP Systems Insight Manager 6.0 User Guide

release, the upgrade process will incorporate the automatic launching of the Identification task against
discovered systems.
-------------------------------------------------------------
The Data Collection task for an Onboard Administrator times out on non-Windows CMS.
Solution: This affects the individual task only and does not affect other tasks in the batch.
-------------------------------------------------------------
Systems Insight Manager might report duplicate entries for array controllers if the data is collected using
both WBEM and SNMP protocols on a HP Insight Management WBEM Providers for Windows Server
2003/2008 target.
Solution: To see the correct data in report, you can perform data collection by disabling one of the protocols.
You can also access SMH to see the correct number of array controllers.
-------------------------------------------------------------
You see a problem with more than two mxinventory processes starting on the CMS.
Solution: Complete the following:
Procedure A-6 Issue with two mxinventory processes starting
1. Verify that your HP-UX CMS has the latest HP-UX kernel patches required for Java 1.5 execution. If the
CMS is HP-UX 11.23 IA/PA, then verify that the PHKL_35029 Kernel patch (or its superseding patch)
is installed. See http://www.hp.com/go/java.
2. Verify that all your HP-UX managed systems have HP WBEM Services for HP-UX A.02.00.11 or newer
and for managed systems running HP-UX 11.23 IA/PA, verify the PHSS_33349 Kernel path (or its
superseding patch) is installed.
-------------------------------------------------------------
If you cancel a running task, by clicking Stop or Delete, and immediately try to start another task of the
same type, the second task does not run until the previously canceled task fully completes the cancellation.
Systems in the cancelled task that are currently being processed are allowed to run to completion. For some
long-running tasks like data collection or software deployment, it can take some time to allow the systems
in progress to reach completion and finally cancel the task.
Solution: If data collection runs for an unusually long time you might want to stop or delete the task, and
wait 5 to 10 minutes after the cancellation has completed before running another data collection task.
If the data collection task is allowed to run to full completion without canceling, another data collection task
cannot be run for at least 15 minutes or the task will fail because it is skipped (this would be shown in the
STDOUT of the task instance).
-------------------------------------------------------------
If you see that data collection failed because of a WBEM connection, it might be caused by a failed WMI
Mapper proxy.
Solution: Complete the following steps:
Procedure A-7 Issue with data collection failing because of WBEM connection
1. Physically verify all of the configured Pegasus WMI Mapper proxies. From the Administrative
toolsServices menu on the server hosting the Pegasus WMI Mapper proxy, be sure the Pegasus
WMI Mapper is running.
2. If not, restart the Pegasus WMI Mapper if possible.
3. If you are unable to restart the proxy or if the Pegasus WMI Mapper was uninstalled, delete it from the
CMS WMI Mapper Proxy settings found in the OptionsProtocol SettingsWMI Mapper Proxy
page.
4. Be sure you have at least one running Pegasus WMI Mapper Proxy configured in Systems Insight
Manager.
5. Verify credentials for the systems.
6. Run identification on all systems.
-------------------------------------------------------------
If data collection of a system fails with the STDOUT error, stating An error occurred connecting
to this system with the WBEM protocol. Check the system configuration
Solution: This might be caused by any of the following conditions:
You failed to make appropriate port number entries in the wbemportlist.xml file:
/etc/opt/mx/config/identificationOn Linux and HP-UX:
128 Troubleshooting