HP Systems Insight Manager 6.2 Installation and Configuration Guide for HP-UX

3 Setting up managed systems
Perform step 2 to install and configure the required management software.
1. Install and configure the CMS. The procedure to complete this step is in the installation chapter of this
guide. For details, see Chapter 2 “Installing HP Systems Insight Manager on the CMS for the first time”.
2. Install and configure the required management software on the systems that will be managed by the
CMS. The procedure to complete this step is in this chapter.
3. Configure Systems Insight Manager for your environment. For more information, see
Chapter 4 “Configuring Systems Insight Manager”.
Setting up managed systems involves installing the required management software. The management software
being installed depends on the type of managed system.
HP-UX
Storage systems
Windows systems -see the
Systems Insight Manager 6.2 Installation and Configuration Guide for
Windows
(http://h18013.www1.hp.com/products/servers/management/hpsim/infolibrary.html)
Linux - see the
Systems Insight Manager 6.2 Installation and Configuration Guide for Linux
(http://
h18013.www1.hp.com/products/servers/management/hpsim/infolibrary.html)
Installing the required software on an HP-UX system
Procedure 3-1 Basic managed system software for HP-UX
1. For HP-UX, the following software, shown with minimum recommended versions, is required for essential
Systems Insight Manager functionality to operate. This software is installed by default as part of the
latest HP-UX 11i v2 or HP-UX 11i v3 operating environments, but it might need to be installed or updated
on older HP-UX 11i v2 systems.
T1471AA HP-UX Secure Shell
OpenSSL
HP WBEM Services for HP-UX
This WBEM Services bundle contains basic system instrumentation that appears in the Systems Insight
Manager Property Pages, as well as supporting data collection and reporting by Systems Insight Manager
inventory functionality. To maximize the value of Systems Insight Manager for properties, inventory,
and events, see http://www.hp.com/go/hpsim/providers for the latest WBEM Services bundle.
2. Ensure the managed system software is installed on HP-UX 11i v2 Update 2. On HP-UX 11i v3, the
listed software's or its equivalences are always installed.
To verify that the minimum required software is installed, log in to the remote system, and run the
following command:
$ swlist l bundle T1471AA B8465BA OpenSSL
If WBEM Services is not found and your operating system is 0603 11.23 OEUR or later, run the following
command:
swlist l product HPUXBaseAux.WBEMServices
To verify that the optional providers and System Management Homepage are installed, run commands
such as:
$ swlist l bundle LVMProvider WBEMP-LAN-00 SysMgmtWeb SysFaultMgmt
OnlineDiag
3. Acquire and install the managed system software if not previously installed.
The SecureShell, WBEM bundles are included on the HP-UX Operating Environment and Application
Release media, as well as part of the Systems Insight Manager HP-UX depot downloaded from
http://h18013.www1.hp.com/products/servers/management/hpsim/dl_hpux.html.
For the WBEM providers, see
http://h18013.www1.hp.com/products/servers/management/hpsim/dl_hpux.html .
Installing the required software on an HP-UX system 23