HP Systems Insight Manager 6.3 User Guide

Setting up HP-UX servers to be managed by Systems Insight Manager
Procedure 3 Setting up HP-UX managed systems
1. Understand the basic managed system software for HP-UX.
For HP-UX, the following software, shown with minimum recommended versions, is required
for essential Systems Insight Manager functionality to operate. This software is installed by
default as part of the latest HP-UX 11i v2 and 11i V3 operating environments, but it might
need to be installed or updated on HP-UX 11i v1 or older HP-UX 11i v2 environments.
T1471AA HP-UX Secure Shell
B8465BA HP WBEM Services for HP-UX
OpenSSL
This WBEM Services bundle contains basic system instrumentation displayed in the Systems
Insight Manager Property pages, supporting collection and reporting by Systems Insight
Manager inventory functionality. To maximize the value of Systems Insight Manager for
properties, inventory, and events, see http://www.hp.com/go/hpsim/providers for the latest
WBEM Services bundle.
If iCap information is desired, also install:
B9073BA version 08.01.01 iCAP for HP-UX
2. Ensure the managed system software is installed.
To verify that the minimum required software is installed, log in to the remote system, and run
the following command:
$ swlist l bundle T1471AA B8465BA OpenSSL
To verify that the optional providers and HP System Management Homepage are installed,
run commands such as:
$ swlist l bundle LVMProvider WBEMP-LAN-00 SysMgmtWeb SysFaultMgmt
OnlineDiag
3. Acquire and install the managed system software if not previously installed.
The SSH and WBEM bundles are included on the HP-UX Operating Environment and
Application Release media, as well as part of the Systems Insight Manager HP-UX depot
downloaded from http://h18013.www1.hp.com/products/servers/management/hpsim/
dl_hpux.html.
For the WBEM providers, see http://h18013.www1.hp.com/products/servers/management/
hpsim/dl_hpux.html .
After you have obtained the depots containing the software, you can install then from the
managed system:
$ swinstall s <depot_location> OpenSSL
NOTE: B8465BA and B9073BA version 08.01.01 depends on OpenSSL, so you must install
OpenSSL first.
$ swinstall s <depot_location> T1471AA
$ swinstall s <depot_location> B8465BA
$ swinstall s <depot_location> <names of WBEM providers being
installed>
After you have verified that the correct management software is installed on your managed systems,
continue to Chapter 4 “Credentials” (page 32) to finish the configuration from the Systems Insight
Manager user interface.
Setting up HP-UX servers to be managed by Systems Insight Manager 27