Deploying HP SIM 5.x on MSCS clusters on Windows 2008 with SQL Server 2005 536992-001, 02/2009

51
Troubleshooting
Note:
This section is applicable only if PMP has been installed manually.
Problem
: Error during MSA tool execution.
Solu
tion:
Execution of MSA tools might fail due to SSH key mismatch. For proper execution of MSA
tools, perform the following:
11.
Make the primary system active and execute
mxagentconfig
to push the
SSH
key to primary
system itself.
AND
12.
Make secondary system act
ive and execute
mxagentconfig
to push the
SSH
key to secondary
system itself.
Problem
: Unable to Single Sign
-
On to client.
Solution:
Client should have the certificate/
n
ame of both cluster systems in it.
13.
If the
Trust mode
is
Trust By Certificate
on the cli
ent, open the Web agent certificate,
cert.pem
file, from both the systems and import them into client Web agent.
14.
If the
Trust mode
i
s
Trust By Name
on the client, include both the system names in trusted server
name list.
Problem
: Unable to get the second
system certificate when browsing to SMH
Solution:
Import the second system certificate on to the first system.