To change the WMI Mapper Proxy port in HP SIM:
1. Log in to HP SIM with Administrative privileges.
2. Verify that the credentials for the CMS are correct:
a. Open the All Systems list and select the HP SIM CMS from the list.
b. Click the Tools & Links tab.
c. Click System Credentials.
d. Select the check box for the CMS instance of WMI Mapper that is running on the local
host.
e. Click Edit system credentials.
f. Verify that the sign-in credentials exist and are correct for the CMS (preferred), or that
there are advanced WBEM settings. Also, verify that the port number is 5989, and that
the credentials are correct for the WMI Mapper. See Figure 26.
Figure 26: CMS system credentials
g. Select OptionsProtocol SettingsWMI Mapper Proxy.
h. Select the CMS instance of WMI Mapper that is running on the local host.
i. Click Edit.
j. Enter 5989 in the Port number field.
k. Click OK to save the settings. See Figure 27.