Deploying HP SIM 6.x on MSCS clusters on Windows 2008 with SQL Server 2008 SP1 White Paper

68
Figure 55: Summary showing services and applications coming online
The installation is now complete.
Validating the installation
To be sure that the HP SIM 6.x service can be moved between both systems, perform the following
steps fr
om either one of the cluster systems:
1.
Open the
Cluster Administrator
and connect to the cluster.
2.
In the
Cluster Administrator
window, on the left pane, right
-
click on the disk group
containing the HP SIM
6.x
program files. For example, HP SIM Disk Group i
s used in this
paper. Select
Move Group
. Be sure that the group fails
-
over to the other system and that all
of the HP SIM
6.x
resources come online.
3.
After the
fail
over occurs on the second system restart the System Management Homepage
service manually on t
he second system.
4.
After waiting a few minutes to ensure that the HP SIM
6.x
service has restarted, go to the
HP SIM
6.x
service through a Web browser using the network name you specified when
creating the HP SIM
6.x
network name resource (W2K
-
CLUS
-
HPSIM in
this paper). The URL
http://W2K
-
CLUS
-
HPSIM:280 specifies the virtual network name and the port of the HP
SIM
6.x