HP Systems Insight Manager 6.2 User Guide

Procedure 7-1 Sending WBEM indications From an HP-UX system
1. From the HP-UX managed system, run /ect/opt/resmon/lbin/send_test_event monitor
name . For example, /etc/opt/resmon/lbin/send_test_event disk_em.
Possible monitor names:
dm_memory
lpmc_em
disk_em
dm_chassis
dm_core_hw
ia64_corehw
fpl_em
2. Confirm that the test indication is shown in the Systems Insight Manager event table view after you
trigger it.
Procedure 7-2 Sending WBEM indications from a Windows system
1. Login to the target Windows system.
2. Go to StartProgramsHP Insight WBEM ProvidersTest WMI events.
3. Click any one of the severities (Informational, Warning, or Error).
4. Click OK to send the test events to the CMS.
Procedure 7-3 Sending SNMP traps from Windows or HP-UX system
1. Run Configure or Repair Agents and on Step 4: Configure or Repair Agents under Configure, select
Send a sample SNMP trap to this instance of Systems Insight Manager to test that events
appear in Systems Insight Manager in the Event list or All Event User Interface for the selected
system.
2. Confirm that the test trap is shown in the Systems Insight Manager event table view after you trigger it.
34 Manage Communications