User's Manual

38 Chapter4
Protocol Specific Configuration
Non-E1/T1 HDLC.FRAME Configuration Values
Non-E1/T1 HDLC.FRAME Configuratio n
Values
Poll Word
AZR - (Z7340A only) Analyzer terminal for received data
Enables this terminal for monitoring frames received on the port. All
received frames are copied, and the copy delivered to the receiving
application for this terminal. This terminal cannot be used to transmit
frames.
AZT - (Z7340A only) Analyzer terminal for transmitted data
Enables this terminal for monitoring frames transmitted on the port. All
transmitted frames are copied, and the copy delivered to the receiving
application for this terminal. This terminal cannot be used to transmit
frames.
CWEN - E nable the use of formatted Cont rol Write requests
If set to one (1), this bit enables the use of formatted control write
requests. See the “Request S pecific Processing” section of Chapter 3 ,
“Using HDLC.FRAME Protocol,” for the format to be used.
RSIG - Report status on CTS or DCD signal state change
If set to one (1), this bit e nables an unsolicited status message to b e
delivered to the receiving application when either of the CTS or DCD
signals is dropped, and when both CT S and DCD are raised.
If this bit is set to zero (0), the HDLC.FRAME t erminal does not report
the state of the CTS and DCD signals.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved (0) AZR AZT 0 CWEN RSIG DSIG RTS Reserved (0)
All reserved bit positions must be filled with zeros (0).