Managing Superdome Complexes: A Guide for HP-UX System Administrators

Configuring and Managing Superdome Partitions
Procedures for Managing Partitions
Chapter 4 165
Step 4. Confirm the partition’s configuration settings.
Use the parstatus -Vp# command to list details about your newly
created and configured partition.
If any configuration details should be modified, use the parmodify
command before booting the partition.
Step 5. Boot your newly created partition.
Use the GSP command menu’s BO command to boot the partition.
# parstatus -Vp1
[Partition]
Partition Number : 1
Partition Name : hostname05
Status : inactive
IP address :
Prmary Boot Path : 4/0/1/0/0.9
ALternate Boot Path : 0/0/0/0/0/0/0/0.0.0
HA Alternate Boot Path : 0/0/0/0/0/0/0/0.0.0
PDC Revision : 104.1
IODCH Version : 23664
CPU Speed : 552 MHz
Core Cell : ?
Core Cell Alternate :
0. cab0,cell4
1. cab0,cell6
[Cell]
CPU Memory Use
OK/ (GB) Core On
Hardware Actual Failed/ OK/ cell Next Par
Location Usage Max Failed Connected To Capable Boot Num
========== ============ ======= ========= =================== ======= ==== ===
cab0,cell4 inactive 4/0/4 2.0/ 0.0 cab 0,bay0,chassis3 yes yes 1
cab0,cell6 inactive 4/0/4 2.0/ 0.0 cab 0,bay1,chassis1 yes yes 1
[Chassis]
Core Connected Par
Hardware location Usage IO To Num
=================== ============ ==== ========== ===
cab 0,bay0,chassis3 inactive yes cab0,cell4 1
cab 0,bay1,chassis1 inactive yes cab0,cell6 1
#