Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Viewing / Setting the Complex Hardware Configuration
Chapter 368
BCH Use this procedure to check cell processor and memory configurations
from a partition’s BCH interface. You can check these details only for the
cells assigned to the local partition.
Step 1. Access the BCH interface for the partition to which the cell is assigned,
and access the BCH information menu.
From the BCH main menu, enter IN to access the BCH information
menu. (If you are not at the BCH main menu, enter MA to go to the main
menu.)
Step 2. From the BCH information menu, check the processor or memory status
for all cells by issuing the PR and ME commands.
GSP:CM> PS
This command displays detailed power and hardware configuration status.
You may display detailed power and hardware status for the following items:
B - Cabinet (UGUY)
C - Cell
G - GSP
I - Core IO
Select Device: c
Enter cabinet number: 0
Enter slot number: 0
HW status for Cell 0 in cabinet 0: NO FAILURE DETECTED
Power status: on, no fault
Boot is not blocked; PDH memory is shared
Attention LED is off
RIO cable status: connected
RIO cable connection physical location: cabinet 0, IO bay 0, IO chassis 1
Core cell is cabinet 0, cell 0
PDH status LEDs: ****
CPUs
0 1 2 3
Populated * * * *
Over temperature
DIMMs populated:
0 . . . 4 . . . 8 . . .12 . . .16 . . .20 . . .24 . . .28 . . .
* * * *
PDC firmware rev 6.0
PDH controller firmware rev 6.0, time stamp: JUL 20 20:40:46 2000
GSP:CM>