Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Viewing / Setting the Complex Hardware Configuration
Chapter 3 69
The BCH information menu’s PR command reports details about all
processors on all active cells in the partition.
The ME command reports details about all active cells’ memory
configurations. The ME command summarizes memory (DIMM) details
for each ranks of memory. Each rank is a set of 4 DIMMs.
These BCH commands do not report details for inactive cells.
HP-UX Commands Use this procedure to check cell processor and memory configurations
from HP-UX running on any of the partitions in the Superdome complex.
You can check these details for any cell in the complex.
Step 1. Log in to HP-UX running on one of the Superdome complex’s partitions.
You can check processor and memory details from HP-UX running on
any of the complex’s partitions.
Information Menu: Enter command > PR
PROCESSOR INFORMATION
Cab/ Processor
Cell Slot CPU Speed HVERSION SVERSION CVERSION State
---- ---- --- -------- -------- -------- -------- -------------
4 0/4 0 552 MHz 0x5c70 0x0491 0x0301 Active
1 552 MHz 0x5c70 0x0491 0x0301 Idle
2 552 MHz 0x5c70 0x0491 0x0301 Idle
3 552 MHz 0x5c70 0x0491 0x0301 Idle
6 0/6 0 552 MHz 0x5c70 0x0491 0x0301 Idle
1 552 MHz 0x5c70 0x0491 0x0301 Idle
2 552 MHz 0x5c70 0x0491 0x0301 Idle
3 552 MHz 0x5c70 0x0491 0x0301 Idle
Information Menu: Enter command > ME
Partition Memory Information
Cell DIMM Rank 0/1 DIMM Rank 2/3 DIMM Rank 4/5 DIMM Rank 6/7
Size Status Size Status Size Status Size Status
---- ------ --------- ------ --------- ------ --------- ------ ---------
4 2048MB Active --- --- ---
--- --- --- ---
6 2048MB Active --- --- ---
--- --- --- ---
Partition Total Memory: 4096
Partition Active Memory: 4096
Partition Deconfigured Memory: 0
* status is scheduled to change on next boot.
Information Menu: Enter command >