Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Viewing / Setting the Complex Hardware Configuration
Chapter 3 75
The following example shows using the PS command to list the PM and
CLU firmware versions for the UGUY utilities board in cabinet
number 1.
BCH Follow this procedure to use the partition’s BCH interface to list the PDC
version installed on active cells within the partition.
Step 1. Access the BCH interface for the partition to which the cells are
assigned, and access the BCH information menu.
From the BCH main menu, enter IN to access the BCH information
menu. (If you are not at the BCH main menu, enter MA to go to the main
menu.)
Step 2. Issue the BCH information menu’s FV command to list the PDC version
installed on all active cells in the partition.
To list both the PDC and PDHC firmware versions for a cell, use the GSP.
GSP:CM> PS
This command displays detailed power and hardware configuration status.
The following GSP bus devices were found:
+----+-----+-----------+----------------+-----------------------------------+
| | | | | Core IOs |
| | | | | IO Bay | IO Bay | IO Bay | IO Bay |
| | | UGUY | Cells | 0 | 1 | 2 | 3 |
|Cab.| | | |IO Chas.|IO Chas.|IO Chas.|IO Chas.|
| # | GSP | CLU | PM |0 1 2 3 4 5 6 7 |0 1 2 3 |0 1 2 3 |0 1 2 3 |0 1 2 3 |
+----+-----+-----+-----+----------------+--------+--------+--------+--------+
| 0 | * | * | * |* * * * * * * * | * * | | | |
| 1 | | * | * |* * * * * * * * | * * | | | |
| 8 | | * | * | | * * | * * | | |
You may display detailed power and hardware status for the following items:
B - Cabinet (UGUY)
C - Cell
G - GSP
I - Core IO
Select Device: b
Enter cabinet number: 1
HW status for SD64000 compute cabinet #1: NO FAILURE DETECTED
PM firmware rev 6.8, time stamp: FRI SEP 22 16:16:19 2000
CLU firmware rev 6.10, time stamp: WED SEP 06 20:56:50 2000
GSP:CM>