Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Viewing / Setting the Complex Hardware Configuration
Chapter 376
The following example shows the FV command displaying the PDC
version for cells 0 and 2 (the only active cells in the partition).
HP-UX Commands Follow this procedure to list the PDC firmware version for any cell in the
Superdome complex from HP-UX.
To list both the PDC and PDHC firmware versions for a cell, use the GSP.
Step 1. Log in to HP-UX running on one of the Superdome complex’s partitions.
You can list any cell’s PDC firmware version fromHP-UX running on any
of the complex’s partitions.
Step 2. Issue the parstatus -V -c
#
command to list details about the specified
cell, including its PDC firmware version.
Information Menu: Enter command > FV
FIRMWARE INFORMATION
PDC ICM PDC Utils
Cell Cab/Slot PDC Ver PDC Date Code Layout Rev XFace Rev
---- -------- ------- ------------- ---------- ---------
00 00/00 006.000 40.34 000 000
02 00/02 006.000 40.34 000 000
Information Menu: Enter command >
# parstatus -V -c2
[Cell]
Hardware Location : cab0,cell2
Global Cell Number : 2
Actual Usage : active base
Normal Usage : base
Connected To : cab0,bay1,chassis3
Core Cell Capable : yes
Firmware Revision : 6.0
Failure Usage : activate
Use On Next Boot : yes
Partition Number : 0
Partition Name : jules00