Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Detecting / Controlling Power in the Complex
Chapter 3 85
Step 2. Issue the PS command from the GSP command menu.
The PS command allows you to list detailed information about
components within the Superdome complex.
The PS command initially reports all cabinets, cells, and core I/O cards it
locates, and prompts you to specify what hardware you want information
about.
Step 3. Specify the cabinet whose components’ status you want to check.
For each cabinet, the PS command reports detailed information that
includes the power status for all components within the cabinet.
The information that the PS command reports for each cabinet includes
the following details:
Cabinet Power—Whether the 48-volt cabinet power switch is on or
off, whether cabinet power is enabled, and details about the
backplane power boards (“BP Power Boards”) and cabinet bulk power
supplies (“BPS” 0–5).
Cell Power—Whether power is enabled and on for all cells within
the cabinet.
Core I/O Card Power—Whether power is enabled and on for all
core I/O cards within the cabinet.
For Superdome complexes that have multiple cabinets, you must check
details for each cabinet separately.
GSP:CM> PS
This command displays detailed power and hardware configuration status.
The following GSP bus devices were found:
+----+-----+-----------+----------------+-----------------------------------+
| | | | | Core IOs |
| | | | | IO Bay | IO Bay | IO Bay | IO Bay |
| | | UGUY | Cells | 0 | 1 | 2 | 3 |
|Cab.| | | |IO Chas.|IO Chas.|IO Chas.|IO Chas.|
| # | GSP | CLU | PM |0 1 2 3 4 5 6 7 |0 1 2 3 |0 1 2 3 |0 1 2 3 |0 1 2 3 |
+----+-----+-----+-----+----------------+--------+--------+--------+--------+
| 0 | * | * | * |* * * * * * * * | * * | | | |
| 1 | | * | * |* * * * * * * * | * * | | | |
| 8 | | * | * | | * * | * * | | |
You may display detailed power and hardware status for the following items:
B - Cabinet (UGUY)
C - Cell
G - GSP
I - Core IO
Select Device: