Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Detecting / Controlling Power in the Complex
Chapter 3 87
Step 2. Issue the HP-UX commands to check the power status for the
Superdome complex components of interest to you.
You can check power status details by using the HP-UX commands
shown in the following list.
For more details on these HP-UX commands, see the manpage for
parstatus (1), frupower (1M), and rad (1M).
This list covers cabinet, cell, I/O chassis, and PCI card slot power.
Cabinet Power—Use the parstatus command for Superdome
cabinet power information.
Specify both the verbose (-V) and cabinet number (-b#) options.
For example, parstatus -V -b0 prints a detailed status for cabinet
number 0.
The parstatus command can give details about each cabinet’s bulk
power supplies (BPS 0–5, if installed) and backplane power boards, in
addition to other details about cabinet fans and blowers.
# parstatus -V -b0
[Cabinet]
Cabinet I/O Bulk Power Backplane
Blowers Fans Supplies Power Boards
OK/ OK/ OK/ OK/
Cab Failed/ Failed/ Failed/ Failed/
Num Cabinet Type N Status N Status N Status N Status GSP
=== ============ ========= ========= ========== ============ ======
0 SD32000 4/ 0/ N+ 5/ 0/ ? 5/ 0/ N+ 3/ 0/ N+ active
Bulk Power Supplies(BPS)
========================
Power Supply 0 ok
Power Supply 1 ok
Power Supply 2 ok
Power Supply 3 ok
Power Supply 4 ok
Backplane Power Boards
======================
Power Supply 0 ok
Power Supply 1 ok
Power Supply 2 ok
Notes: N+ = There are one or more spare items (fans/power supplies).
N = The number of items meets but does not exceed the need.
N- = There are insufficient items to meet the need.
? = The adequacy of the cooling system/power supplies is unknown.
#