Managing Superdome Complexes: A Guide for HP-UX System Administrators

Managing the Overall Complex
Detecting / Controlling Power in the Complex
Chapter 390
NOTE For safety reasons do not rely on this value unless you have just updated
the display by rescanning the complex. Cell boards may have changed
state if time has passed since the last complex scan.
To force a rescan of the complex, hit the Rescan Complex button in the
lower-right corner of the Complex Details window.
How to Determine if an I/O Chassis has Power:
Step 1. Run the Partition Manager (parmgr).
The Partition Manager can be run from:
an HP-UX command line
a Web browser
the System Administration Manager utility (SAM)
For details see “How to Start The Partition Manager” on page 141.
Step 2. From the Complex menu, select Show Complex Details. This will
bring up a new window with several panels of information about the
complex.
Step 3. Click on the tab marked I/O Chassis to bring up the panel that
contains the status of the I/O Chassis in the complex.