HP-UX Remote Access Services Administrator's Guide

defaultserver incmail <emailaddress>
deny-email <case-insensitive-email-address>
If you specify virtual host addresses, addresses only on a particular host receive
notification messages of anonymous uploads. Otherwise, notifications are sent to the
global addresses.
The defaultserver addresses apply only to real hosts and not to virtual hosts. Hence,
the real host receives notifications of uploads on its default anonymous area. However,
with this option set, the virtual hosts are not notified. For more information on the
email-on-load feature, type man 4 ftpaccess at the HP-UX prompt.
Following are examples of the email-on-load feature:
mailserver abc.com
Specifies the name of a mail server that accepts upload notifications for the FTP daemon.
You can use this option to notify any user of anonymous uploads.
incmail def@abc.com
Specifies the email addresses to be notified of anonymous uploads.
mailfrom ghi@abc.com
Specifies the senders email address for anonymous upload notifications.
Timeouts
You can configure timeout values used within the FTP daemon by using the timeout
options. Table 2-2 describes the FTP daemon timeout values.
Table 2-2 FTP Daemon timeout Options
DescriptionOption
The time period for which the daemon waits for an incoming (PASV-passive) data
connection. The default value is 120 seconds.
accept
The time period the daemon waits before attempting to establish an outgoing
(PORT-port) data connection. The default value is 120 seconds. This affects the actual
connection attempt. The daemon makes several attempts at regular intervals, sleeping
between each attempt, before disconnecting. During the 120-minute timeframe, the
daemon continues its attempt to establish a connection. If the daemon fails to establish
a connection during this time period, it disconnects.
connect
The time period the daemon waits for some activity on the data connection. The
default value is 1200 seconds.
data
Additional Clauses in ftpaccess 47