Installing and Administering HP EISA FDDI/9000 and HP HSC FDDI/9000

70 Chapter 5
Troubleshooting
Using the fddilink Utility
PHY: ConPol Cutoff Alarm ConState RemoteType RemoteMAC PCM LER
A 0000 7 8 CONNECTING ? 0 BREAK 9
B 0000 7 8 ACTIVE S 1 ACTIVE 11
T-MAX Low: 1336.934 ms MAC Attribute Counts
TVX Low: 5.222 ms Frame : 0x000001F0 Error : 0x00000000
T-Req : 165.007 ms Copied : 0x000000C5 Lost : 0x00000000
T-Neg : 165.000 ms Transmit : 0x00000123 TvxExpired: 0x00000001
T-Max : 167.772 ms Frame/sec: 0x00000000 NotCopied : 0x00000003
TvxValue : 2.519 ms Token : 0x00000000 Late : 0x0000
RingOp : 0x00000000
-- Exit-<ESC> ----------------------- Menu --------------------- More-<Space> -
- 1:Composite 2:SMT 3:MAC 4:Counters 5:Port-A 6:Port-B 7:Path 8: N/A 9:Delay
:Poll Rate = 1000 MS Composite Data
StationID : 1000 906B 01DC ECM-IN CFM-C_WRAP_B RMT-RING_OP
ManufactureData: XDI731-Interphase Corp.
UserData : P5511-Interphase Corp.
Lem PHYA: 0x00000000 Reject: 0x00000000
Lem PHYB: 0x00000000 Reject: 0x00000000
MAC Count: 0x01 ConfigCap : 0x0000
NonMaster: 0x02 ConfigPol : 0x0000
Master : 0x00 ConnectPol : 0x8000
PathsAval: 0x03
-- Exit-<ESC> ----------------------- Menu --------------------- More-<Space> --
1:Composite 2:SMT 3:MAC 4:Counters 5:Port-A 6:Port-B 7:Path 8: N/A 9:Delay
NOTE Select option 9: Delay at the bottom of the screen to start polling the
adapter at the regular intervals. Otherwise, the display will only be
updated with the current information when other menu options are
selected.
The parameters most commonly used are defined below:
Poll Rate indicates the rate at which values are updated. This value
can be changed by the Delay function (option 9 at the bottom of the
screen).
StationID indicates the FDDI address (in non-canonical order) of the
station from which the fddilink utility starts.
ECM indicates the Entity Coordination Management. The In state is
the normal state for a completed connection.