User ID (UID) :0 Log Class :DISASTE
R
Device ID :1 Path ID :0
Connection ID :0 Log Instance:0
˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜
˜
<1317> Token Ring driver encountered a lobe error on
interface unit <1>; reset or reboot
(Disaster) Verify the physical connections from your syste
m to the ring. Then use the lanscan(1M) command to find th
e NMID of the Token Ring card. Use the lanadmin(1M) comman
d to reset the card. Reboot if necessary. If rebooting is
ineffective, follow the troubleshooting flowcharts in the
documentation in sequence until the problem is solved. The
HP internal error code is <-1>.
To examine just the log messages in the log file:
netfmt -f /var/adm/nettl.LOG00
A sample Token Ring log message using just the -f option is shown
below.
***********************802.5 Networking*******************
*
Timestamp :Mon Dec 12PST 1994 03:40:10.555252
Process ID :750 Subsystem :TOKEN
User ID (UID) :0 Log Class :DISASTE
R
Device ID :1 Path ID :0
Connection ID :0 Log Instance:0
˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜
˜
<1317> Token Ring driver encountered a lobe error on inter
face unit <1>; reset or reboot
To check network logging and tracing status:
nettl -status
For non-PCI systems, to start Token Ring tracing to the file
/tmp/tracefile.TRC0:
nettl -traceon all -entity token -file /tmp/tracefile
nettl(1m) adds the .TRC0 postfix for you.
For PCI systems, to start Token Ring tracing: