Interface Card OL* Support Guide

Chapter 2
pdweb - Peripheral Device Tool Web Interface
Starting and Stopping the pdweb Server
27
NOTE If you are starting pdweb from SAM, you do not need to manually start the pdweb server as it is
started automatically when Cards and Devices is selected. Refer to “Using SAM” on page 29 for
more information.
Stopping or Restarting the pdweb Server
You must have superuser capability to start the pdweb server. Restarting stops the pdweb server, then starts it
again. To start the pdweb server on a target host system:
Step 1. Log into the host system as root.
Step 2. Enter pdweb -s
action
where
action
is either stop or restart
The HP Apache and pdweb Web servers are both stopped or restarted depending on your action.
Restarting stops the pdweb server, then starts it again.
Starting the pdweb Server with No Timeout
You can start the pdweb Web server with the inactivity timeout feature disabled using the -s option. This
causes the pdweb server to run in a mode where it does not exit after a period of inactivity. This feature is
helpful in instances when you want to use pdweb several times throughout the day but don't want to configure
the autostart capability. Individual Client Web browser login sessions will still timeout, but you can log back
in without having to restart the pdweb Web server.
Step 1. Log into the host system as root.
Step 2. Enter pdweb -s startssl
The HP Apache and pdweb Web servers are both started.
Autostarting the pdweb Server and GUI
It is possible to start both the pdweb Web server and GUI client components automatically from a supported
Web browser:
Step 1. Enable the pdweb autostart feature with waconf (1M):
a. Log into the host system as root.
b. Enter waconf -a on
Now the pdweb autostart feature can be used. Once the autostart behavior is configured, it remains
on or off until waconf is executed to change it. The configured behavior is remembered regardless of
system rebooting.
Step 2. Open a Web browser on any network client that is connected to your company intranet.
Step 3. Enter http://hostname:1110/pd/pd.cgi where hostname is the hostname of the target host
system.
Once the pdweb Web server components have been started, the HP SAM WEB login screen is presented so
that you can log into the Peripheral Device Tool.