Migrating X.25 over PSI to XOL

9
Field Format Description
0x.
0x7e, both inclusive. If the value for SSAP is not
provided, then SSAP takes the value of DSAP.
standby_device**
Device name string.
Example: lan2
Name of the standby LAN device used for local
failover. Required only for local failover support.
For more information about this parameter, see HP
X.25/9000 User's Guide available at:
http://docs.hp.com/en/netcom.html#X.25
XOL_floating_macaddr**
Hexadecimal value
This value must be prefixed
with 0x
The unique MAC address for the LAN card in the LAN
subnet. Required only for local failover support.
For more information about this parameter, see HP
X.25/9000 User's Guide available at:
http://docs.hp.com/en/netcom.html#X.25
** Required for the High Availability feature
The XOL interface does not support packet sizes greater than 1024 bytes in Layer 3. If the Layer 3
packet size is reduced after migration to XOL, the reduced packet size must conform to the
application requirements.
The following parameters do not support values greater than 1024 in the configuration file:
def_inpacketsize
def_outpacketsize
neg_inpacketsize
neg_outpacketsize
Configuration file for an X.25 interface over PSI
Following is the generic configuration file for an X.25 interface over PSI:
#cat /etc/x25/x25config
#
#X.25 Initialization File Created: Thu Jul 13 15:19:38 2006
#
#
# Global Parameters
#
x.121 35011
x.121_packetaddr 35011
device x25_1p2
name x25_interface_name
#
# Level 2 Parameters
#
t1 3000
t3 60000
framesize 149
n2 20
l2window 7
#
# Level 3 Parameters
#
networktype DTE_88
#
# Circuit Table Definition
#
# LCI TYPE HOW MANY