HP-UX 11i v3 Installation and Update Guide, March 2013

Table 10 Updating tips (continued)
TipTopic
NIS+ to LDAP-UX migration tool uses NIS+ commands and utilities for migration. Since the
NIS+ commands and utilities are not available on HP-UX 11i v3, the migration tools will not
run on a system that has been updated to HP-UX 11i v3.
What to do
Migrate NIS+ servers and clients to LDAP before updating to HP-UX 11i v3.
Starting with the HP-UX 11i v3 March 2008 release, Online Diagnostics are no longer
started by default. Traditionally, HP Instant Support Enterprise Edition (ISEE) depends on
ISEE users might need to
switch diagnostics mode
Online Diagnostics (EMS listener) for event detection; however, if it is not started and you
notice anomalies in ISEE operation, especially with regard to which events are submitted,
you must consult the ISEE Installation and Configuration Guide.
What to do
To check which version of diagnostics is running, run the following command:
sfmconfig -w -e
The preceding command switches the diagnostics mode to "EMS". In this mode, EMS
Hardware Monitors are enabled and SysFaultMgmt does not monitor any devices.
If the results show that only System Fault Manager is running without Online Diagnostics
(EMS listener) on your HP-UX device, and anomalies exist in ISEE operation, especially with
regard to which events are submitted, consult the ISEE Installation and Configuration Guide
for additional information and instructions at
www.hp.com/learn/isee
Note: As of the HP-UX 11i v3 September 2008 OEUR, ISEE is no longer included in the
OEs. See the HP-UX 11i Version 3 September 2008 Release Notes for further information.
The update-ux command returns an error value when it is not successful:In case of trouble
1 - Error during execution; update aborted.
2 - Update aborted via user action (keyboard press)
Messages are recorded in /var/opt/swm/swm.log and /var/adm/sw/
update-ux.log.
If you encounter a problem during the update process, review Appendix A: “Harmless
messages and known problems” (page 72) for possible solutions.
Proceeding with updating
After you have completed all necessary preparations and have familiarized yourself with any
special issues, you can update your target system. You can update to HP-UX 11i v3 using one of
the following methods:
update-ux terminal user interface. See “Updating to HP-UX 11i v3 using the terminal user
interface” (page 49).
update-ux command line interface. See “Updating to HP-UX 11i v3 using the command
line interface” (page 56).
Updating to HP-UX 11i v3 using the terminal user interface
This section describes how to update your system using the update-ux Terminal User Interface
(TUI).
There are seven steps in the TUI update-ux process:
Step 1: Start-up Start the update-ux TUI.
Step 2: Select source Provide the location of the software depot from which the
software will be installed.
Step 3: Select OE Select the OE to which you want to update.
Proceeding with updating 49