HP Instant Capacity Version 10.x User Guide (5900-1581, March 2011)

4. Mount the DVD drive to the desired directory. The following example uses the /dev/dsk/
c1t2d0 device file (from step 2) and the /dvd directory. To mount the DVD drive, enter a
similar command as:
mount -r /dev/dsk/c1t2d0 /dvd
5. Install the B.10.x bundle B9073BA from the DVD:
swinstall -s /dvd B9073BA
6. Continue with “For All HP-UX Installations” (page 34).
Installing from the HP Software Depot (For HP-UX 11i v1, 11i v2, and 11i v3):
1. Search for B9073BA on the HP Software Depot website:
http://www.hp.com/go/softwaredepot
2. Select the link that appeared as a result of your search, and follow the instructions on the
Installation page.
3. Continue with “For All HP-UX Installations” (page 34).
For All HP-UX Installations
After you have successfully installed the Instant Capacity software using the swinstall command,
perform the following procedure to validate your installation:
1. Execute the /usr/sbin/icapstatus command.
2. Verify that the icapstatus command output indicates the correct number of components
without usage rights for cells, cores, and memory.
If any number is incorrect, contact your local HP Response Center and request iCAP assistance.
3. Log in as root
4. Set the system contact information by entering the following command:
/usr/sbin/icapmodify -c <contact_email_address>
5. If you want to configure asset reporting, then ensure that outgoing mail can be sent to HP mail
servers from your system, even if the system is behind a firewall. See “Diagnosing Email
Configuration” (page 105).
Test the transmission of your asset report, via email to HP, by entering the following
command:
/usr/sbin/icapnotify <reply_address>
The icapnotify command sends an asset report to HP, root, and the supplied reply
address.
HP responds with an email to the reply address after the asset report is received.
Use an email client to verify the return email from HP to the reply email address.
Installing Instant Capacity on OpenVMS Systems
On OpenVMS systems, the Instant Capacity software is automatically installed on partitionable
systems when the OpenVMS Version 8.3 or later operating system in installed. You should not
need to install the Instant Capacity software separately on OpenVMS systems. Instant Capacity
hardware components have already been configured at the factory before delivery. The Instant
Capacity software is included on the OpenVMS Version 8.3 Operating Systems media.
To verify that the Instant Capacity software is installed and configured, run the following OpenVMS
commands:
$ @sys$manager:ICAP$CLI_UTILS.COM CONFIG_CHECK
$ show log ICAP$CONFIGURED
"ICAP$CONFIGURED" = "TRUE" (LNM$JOB_nnnnnnnn)
34 Installing and Removing Instant Capacity Software