Example 2 Sample Session of icapstatus (on HP-UX)
> /usr/sbin/icapstatus
Software version: B.11.31.09.00.00.71
System ID: supericod
Serial number: 1234567890
Product number: A6912A
Unique ID: fffff-fff-ffffff-ffff
System contact e-mail: mjones@corp.com
From e-mail: Set to the default ('adm')
Asset reporting: on
Temporary capacity warning period: 15 days
Exception status: No exception
Local nPartition Status (09/17/08 12:34:56)
-------------------------------------------
Total number of configured cores: 8
Number of Intended Active cores: 7
Number of active cores: 6
Number of inactive cores: 2
Additional cores that can be activated with current usage rights: 1
Number of cores that could be activated with additional usage rights: 1
Number of cores that can be activated with temporary capacity: 0
Number of cores that are deconfigured or attached to inactive cells: 0
Instant Capacity Resource Summary
---------------------------------
Number of cells without usage rights: 0
Number of inactive cells: 0
Amount of memory without usage rights: 0.0 GB
Amount of inactive memory: 0.0 GB
Number of cores without usage rights: 4
Number of inactive cores: 6
Number of cores that must be deactivated (insufficient usage rights): 0
Temporary capacity available: 0 days, 0 hours, 0 minutes
Allocation of Instant Capacity Resources among the nPartitions
--------------------------------------------------------------
Intended Actual
nPar Total Active Active =======Inactive======= Runs
ID Cores Cores Cores Cores Memory Cells iCAP nPar Name
==== ===== ======== ====== ====================== ==== ====================
0 8 5 4 4 0.0 GB 0 Yes Partition 0
1 8 7 6 2 0.0 GB 0 Yes Partition 1 (local)
N/A 0 N/A N/A N/A 0.0 GB 0 N/A Unassigned Cells
Setting System Contact Information
HP recommends that you specify a system contact’s email address on each partition in your system.
On OpenVMS systems, the email address may be a logical pointing to a distribution list.
If specified, the system contact receives the following types of Instant Capacity email:
Configuration change notification when cores are activated or deactivated
Compliance exception notification
Temporary capacity expiration notification
Instant Capacity enforcement notification
Virtual partition boot time compliance notification
If participating in a GiCAP group and a hardware incompatibility is detected (see “Upgrades
and Global Instant Capacity” (page 83))
Setting System Contact Information 39