Instant Capacity on Demand (iCOD) User's Guide for versions B.05.x

Special Considerations
Differences Between Supported Platforms
Appendix B132
On iCOD
Superdome
Systems:
When running the iCOD software on hardware-partitionable systems,
the number of iCOD processors is audited for your complex as a whole,
not an individual partition. iCOD software must be installed and
configured on all partitions that contain iCOD processors. It is important
not to remove the iCOD software from all partitions in your complex
unless you have activated and purchased all iCOD processors.
Activation of processors in offline activation mode on Superdome systems
is not a user executable operation. If you use the offline activation
method and you wish to activate a processor, you need to contact your
HP service representative.
If you are running OpenView measurement products, such as the
GlancePlus Pak, HP recommends that you update to version C.03.20 or
later.
Also, see the information on “Too Many Processors Activated on iCOD”
on page 74, in the Frequently Asked Questions chapter.