Instant Capacity on Demand (iCOD) User's Guide for versions B.05.x

Installing and Uninstalling iCOD Software
Updating/Installing iCOD Software
Chapter 342
Updating/Installing iCOD Software
Factory Integrated
Systems
You do not need to install the iCOD software if your processors and
software were ordered with your HP enterprise server. The iCOD
software was already installed by HP prior to delivery. You can use the
following command to verify that the iCOD software is installed and
configured:
/usr/sbin/icod_stat
IMPORTANT OpenView measure products (such as MeasureWare and GlancePlus)
must be updated to version C.02.60 or later before installing or updating
the iCOD software. For details see “Measurement Software on iCOD
Systems” on page 130.
If you currently have an iCOD software version installed that is prior to
version B.04.x (for example: B.01.00, B.02.x, or B.03.x) you need to
update your system to iCOD version B.05.01. It is recommended to
update to iCOD version B.05.01 if you currently have version B.04.x
installed. You can contact your HP service representative to update and
reconfigure your system to version B.05.01. However, below are
instructions for installing version B.05.01 (for HP-UX 11.0 and 11i v1)
from the Support Plus CD-ROM and Software Depot
(software.hp.com). These instructions can be used to upgrade an
existing iCOD system to version B.05.01, or to install version B.05.01 on
a newly configured iCOD system.
How To Find The Latest Patches
This document lists the patches required to install and run iCOD B.05.x
known at the time of publication. To find the most current patches, go to
the HP Software Depot at software.hp.com and perform the following
steps:
Step 1. Click on
Search, enter the iCOD software product number B9073AA, then
click on the Search button
Step 2. Click on the link that appears as a result of your search
Step 3. Click on the
installation link