How to migrate HP-UX workloads between physical and virtual servers easily

12
Figure 11. Servers seen by IO
Verifying NPIV support in an HP Integrity VM host
The following explains how to verify the support of the NPIV technology on visor1 that will host the v2p2v_ls
logical server:
List all Fiber Channel capable devices:
visor1# ioscan -funC fc | grep dev
/dev/fcd0
/dev/fcd1
Verify the support of NPIV by the Fiber Channel devices:
visor1# fcmsutil /dev/fcd0 | grep NPIV
NPIV Supported = YES
visor1# fcmsutil /dev/fcd1 | grep NPIV
NPIV Supported = YES
Detailed NPIV information can be obtained relative to a specific FC device:
visor1# fcmsutil /dev/fcd0 npiv_info
PFC Hardware Path = 0/0/0/7/0/0/0
PFC DSF = /dev/fcd0
PFC Class Instance = 0
PFC Driver state = ONLINE
PFC Port WWN = 0x5001438002a3000c
PFC Node WWN = 0x5001438002a3000d
PFC Switch Port WWN = 0x200600051e028198
PFC Switch Node WWN = 0x100000051e028198
FlexFC Virtual Fibre Channel (VFC)
----------------------------------
Maximum Supported FlexFC VFC = 8