HP-UX Virtual Partitions Administrator's Guide (includes A.05.02)

Installing, Updating, or Removing vPars and Upgrading Servers with vPars
Updating from vPars A.03.xx to A.04.xx
Chapter 4
98
Bundle Names
For HP-UX 11i v2, the possible OE bundles are listed below.
HPUX11i-OE Foundation OE
HPUX11i-OE-Ent Enterprise OE
HPUX11i-OE-MC Mission Critical OE
You should chose the same OE that your current virtual partition is running. Use the swinstall
command to check which OE you are currently running:
# swlist -l bundle | grep -i OE
HPUX11i-OE-Ent B.11.23.0505 HP-UX Enterprise Operating Environment
T1335BC is the vPars A.04.xx bundle.
NOTE Be sure that both the OE and vPars bundles are specified on the update-ux command line.
6. After the all updates for the above virtual partitions have completed, use Update-UX to install the latest
OE and vPars bundle to the first virtual partition.
Example:
keira1 # update-ux -s depot1:/release/0505.1123/HPUX11i-OE-Ent.DVD HPUX11i-OE-Ent T1335BC
Although you can do all the updates in parallel, you need to make sure that all of the other virtual
partition updates have successfully performed the updating to the point of halting for reboot. In the next
step, the entire nPartition will be rebooted; if the other virtual partitions are still in progress of updating,
the OS instances may be in an unknown state.
NOTE If the BOOT and ALTBOOT disks are a mirrored pair, updating is not required on the
ALTBOOT disk. Otherwise, after updating the OS on the primary boot path disk, boot the
virtual partitions from the alternate path boot disk and repeat the update-ux procedure.
For example, if keira2 has an alternate boot disk that is not a mirror of the primary boot
disk, and you wish to update the OS on the alternate boot disk, boot keira2 from the
alternate boot path using:
MON> vparload -p keira2 -B ALT
and repeat the update-ux procedure
keira2# update-ux -s depot1:/release/0505.1123/HPUX11i-OE-Ent.DVD HPUX11i-OE-Ent T1335BC
7. Reboot the nPartition to ISL>
Example:
MON> reboot
NOTE At this point, you need to reboot the nPartition from the MON> prompt, not just the virtual
partition. By rebooting the nPartition, you can load the new vPars Monitor in the next step.