HP-UX Virtual Partitions Release Notes A.05.08

Topology of A5158A Changes from Fabric to Public Loop After the Virtual
Partition Reboots
Related Defect ID and Patch Number
JAGaf15533
Applicable On
vPars A.05.xx on PA-RISC
vPars A.04.xx on PA-RISC
vPars A.03.xx on PA-RISC
Description
When the A5158A is connected to the Brocade 2800 or 12000 switch, the topology of the
A5158A changes after the virtual partition reboots.
Symptoms
Before a reboot, the topology shows PTTOPT_FABRIC:
vpar1# tdutil /dev/td0
Vendor ID is = 0x00103c
Device ID is = 0x001028
TL Chip Revision No is = 2.3
PCI Sub-system Vendor ID is = 0x00103c
PCI Sub-system ID is = 0x000006
Topology = PTTOPT_FABRIC
...
After a reboot, the topology shows PUBLIC_LOOP:
vpar1# tdutil /dev/td0
Vendor ID is = 0x00103c
Device ID is = 0x001028
TL Chip Revision No is = 2.3
PCI Sub-system Vendor ID is = 0x00103c
PCI Sub-system ID is = 0x000006
Topology = PUBLIC_LOOP
...
Logging into the switch, the switch information before the reboot shows:
brocade01:admin> switchshow
switchName: brocade01
switchType: 2.4
switchState: Online
switchMode: Native
...
port 0: -- No_Module
port 1: -- No_Module
port 2: -- No_Module
port 3: sw Online F-Port 50:06:0b:00:00:10:23:fa
port 4: sw Online F-Port 50:06:0b:00:00:00:f4:28
The switch information after the reboot shows:
brocade01:admin> switchshow
switchName: brocade01
switchType: 2.4
switchState: Online
switchMode: Native
...
port 0: -- No_Module
port 1: -- No_Module
port 2: -- No_Module