HP-UX Virtual Partitions Release Notes (A.05.09)

Applicable On
vPars on PA-RISC
Description
Using a fibre channel mass storage device going through a Brocade 3800 switch with firmware
version 3.1.1, autobooting virtual partitions fails on rp5405, L3000/rp5470, or
N4000/rp7400 servers with PDC 43.22 installed.
Symptoms
Autoboot fails.
Workaround
Boot the virtual partitions manually from the vPars Monitor or HP-UX shell prompt. For example:
MON> vparload -p vpar2
or
vpar1# vparboot -p vpar2
For more information on using vPars with fibre channel devices, see the HP-UX Virtual Partitions
Ordering and Configuration Guide.
On sx2000 Integrity Servers, Booting an OS Kernel while in the Wrong
Mode May Cause a Panic Instead of Displaying Error Messages
Related JAG or Patch ID Number
JAGag06132
Applicable On
vPars A.05.xx on Integrity
vPars A.04.xx on Integrity
Description
On Integrity servers, if you are in vPars mode and you boot the OS Kernel (boot vmunix)
instead of the vPars Monitor (boot vpmon), an error message is typically displayed on the
console. You may, however, receive a system panic message, instead of an error message.
Symptoms
The system panic displays messages similar to the following
EFI\HPUX\AUTO ==> boot vmunix
................
Launching /stand/vmunix
SIZE: Text:29561K + Data:7016K + BSS:7128K = Total:43705K
Console is on virtual console
Booting kernel...
Stored message buffer up to panic:
5028, 0x11, 0x40).
pinned_pdk_malloc_avail_contig(): 0x33000
Bad News: Cannot use the Kernel Stack when interrupted on the ICS.
Bad News: Fault/trap with interrupts disabled and we cared.
reg_dump(): Displaying register values (in hex) from the save state
...
System Panic:
double panic: Bad News!
Workaround
After the system comes back up, make sure the system is in the mode you want (vPars or
nPars), then boot the appropriate item (vpmon for vPars mode and vmunix for nPars mode).
16 vPars A.05.09 Release Notes