HP Superdome 2 Partitioning Administrator Guide (5900-1801, August 2011)

ILM granule size at next boot : 1024 MB
SLM granule size : 1024 MB
SLM granule size at next boot : 1024 MB
Max number of ILM granules possible : 1024
Max number of SLM granules possible : 1024
User Specified Max number of blades : 8
Max number of blades at next boot : 8
User Specified Max number of vpars : 16
Max number of vpars at next boot : 16
Current boot mode : npars
Next boot mode : npars
Parspec Change Policy : Enabled
VGA : Enabled
VGA next boot mode : Enabled
Pending Deletion : -
parstatus -C
[Blade]
Enclosure/ Usage/ CPU Memory (GB) Use Par Pending
Blade Status* OK/ (GB) On Num Deletion
Indicted/ OK/ Next
Deconf Indicted/ Boot
Max Deconf
=== =================== ======= ============= ====== ====== ==========
1/5 InActive Base/OK 8/0/0/8 16.0/0.0/0.0 yes 2 -
1/7 Inactive Base/OK 8/0/0/8 16.0/0.0/0.0 yes 2 -
* D-Degraded I-Indicted
NOTE: On SD2, for an nPar in npar mode, nPars are created with a default ILM/SLM distribution
of 1:7 when no value is specified for SLM. For an nPar created in vpar mode, the default is to use
100% ILM.
Operating system specific default values for nPartition attributes
When an nPartition is created for a specific operating system type, the default values specific to
that operating system type are applied to the nPartition attributes. By default, hyperthreading is
enabled when nPartitions are created to run HP-UX. The default attribute values are applied without
a need for user intervention. The partition management software applies pre-determined OS specific
defaults when you create a partition for a specific operating system type. However, there is also
support for a new pardefault command, which displays the operating system specific attribute
values and allows users to change them if needed:
pardefault
[Original Defaults]
Parcon Default OS Type : HPUX_11iV3
OS Type : HPUX_11iV3
Hyper Threading at activation : Enabled
SLM Percentage : 87.50%
ILM granule size : 1024 MB
SLM granule size : 1024 MB
VGA : Enabled
[Current Defaults]
Parcon Default OS Type : HPUX_11iV3
OS Type : HPUX_11iV3
Hyper Threading at activation : Enabled
SLM Percentage : 87.50%
Operating system specific default values for nPartition attributes 25