OSI Troubleshooting Guide, May 1997

42 Chapter 1
Interoperability Testing
Interpreting X.25 Errors
Interpreting X.25 Errors
The following are possible situations you may currently find yourself in.
X.25 problem corrected.
If you have made a change that corrected your X.25 problem, then
proceed to the Transport layer tests.
Configuration change required.
If the corrective action in the following sections require you to change a
configuration parameter, then do so and rerun the X.25 test.
Problem persists.
If you have been unsuccessful in correcting the problem, gather the
information you have collected to provide to your HP support
representative.
Table 1-6 X.25 Errors
Error Reason Action
socket() X.25 is not installed on your
system.
Install X.25.
bind() If OTS is running, osidiag is
not able to bind to the same
X.121 address the stack is
using.
If supported by a switch, try binding to a
different subaddress or the NULL
subaddress.
connect() Invalid programmatic
access name.
Use default or leave blank. Can also verify
the value by issuing the “Status...
operation through the X.25 Tests.