OSI Troubleshooting Guide, May 1997

50 Chapter 1
Interoperability Testing
Reason and Refuse Codes
(0xF9) Protocol Error Detected by Local Transport
Error encountered decoding a PDU sent by
the remote Transport entity.
Generate a trace and contact
your HP support
representative.
(0xFA) Protocol Error Detected by Local Session
Error encountered decoding a PDU sent by
the remote Transport entity.
Generate a trace and contact
your HP support
representative.
(0xFC) Insufficient Resources for Local Transport
Stack experiencing resource problems.
Examine other OTS
processes running. Contact
HP support representative if
condition persists.
(0xFD) Insufficient Resources for Local Session
Stack experiencing resource problems.
Examine other OTS
processes running. Contact
HP support representative if
condition persists.
(0xFE) Insufficient Resources for Local
ACSE/Presentation
Stack experiencing resource problems.
Examine other OTS
processes running. Are you
near the 448 connection limit?
Contact HP support
representative if condition
persists.
(0xFF) Local User Error
Usually caused by overriding parameter
default values, Could result from trying to
run an operation in the wrong state.
Check parameters values you
changed.
(01-EF
X.25
F0-FF
Transport
Code Unknown
An unrecognized error code was received.
Examine documentation of
other vendor for disconnect
reason codes. If X.25 range,
run an X.25 connection test,
the diagnostic information
may be helpful.
Code Meaning Action