HP-UX 11i v3 Installation and Update Guide, March 2014

Known install and update problems
Table 16 describes problems currently known to occur while installing and/or updating to HP-UX
11i v3.
Table 16 Known install and update problems
Description/actionProblem
PHKL_43527 (which is part of 1403 QPK) causes a behavior in which
vxconfigd(1M) might hang when doing vxresize(1M) on a mirrored volume with
When doing
vxresize
(1M) on a
mirrored volume with DCO version
DCO version 20 configured. Even if the resize does not hang, there is a possibility20 configured,
vxconfigd
(1M)
might hang. that a panic might occur when taking a snapshot of the volume using the DCO 20
configured. If such behavior occurs, vxconfigd might hang in trying to start up
the mirrored volume involved in subsequent reboots. The behavior is due to a
corruption to the DCO 20 map introduced when resizing a mirrored volume having
no snapshot or detached-plex at the time of resize.
What to do
Install PHKL_43779 and PHCO_43824 which contains the fix.
When using swinstall to install or update the SATADVD-00 driver version 1203
or lower to later versions, the system might hang if the Utilization Provider Daemon
If Utilization Provider Daemon
nl
(/usr/lbin/utild) is running
during installation or update of
(/usr/lbin/utild) is active. This issue is known to occur on a system with
SATADVD device support (For example, rx2800 i2 systems).
SATADVD-00 product versions
What to do
1203 or lower to later versions,
the system might hang.
Before updating the SATADVD-00 driver with swinstall, stop /usr/lbin/
utild, and then restart it after installing or updating the driver. For more
information including instructions for halting utild, see SATADVD-00 (satadvd)
B.11.31.1403 Mass Storage Driver Release Notes at http://www.hp.com/go/
general-io-docs.
During the removal of CDE-* bundles, you will see the following error in the rc.log
file after reboot:
After containment subsystem configuration is finished. The output from
"/sbin/rc2.d/S480sec_late_init start":
When CDE-* bundles are removed,
the "/sbin/rc2.d/
S480sec_late_init start"
script might fail
setfilexsec: warning: Ignored the entry for file
"/usr/dt/bin/dtsession": No such file or directory
ERROR CODE 1 "/sbin/rc2.d/S480sec_late_init start" FAILED
What to do
While installing the CDE-* bundles, privileges will be given to /usr/dt/bin/
dtsession through configure script. While removing the bundle, privileges are
not dropped for the same binary using unconfigure script as a result the error
occurs.
To avoid the error, run the following command after the removal of CDE-* locale
bundles:
setfilexsec D /usr/dt/bin/dtsession
After the successful installation of HP-UX on volumes greater than 2 TB, BOOT
might fail with the following message:
When SAS boot disk size is greater
than 2 TB, HP-UX boot might fail
on HP Integrity servers
Press Any Key to interrupt Autoboot
\EFI\HPUX\AUTO ==> boot vmunix
Seconds left till autoboot - 0
AUTOBOOTING...> System Memory = 65383 MB
loading section 0
Error - efi_disk_read returned (Invalid Parameter)
offset:0xf4e00000, ma:0x80040000, len: 262144
pausing temporarily... 0
Read Error(elf_load):read 262144 bytes out of 524288 bytes
requested.
loading failed
What to do
See the Customer Resolution Notes in QXCR1001260030 at the HP Support Center
(http://hp.com/go/hpsc). Click Search HP Support Center, then select Search by
document ID for your search mode. Enter "ttr_na-SSB_1001260030” in the box.
Known install and update problems 77