VERITAS File System 4.1 Administrator's Guide

Kernel Messages
Kernel Messages
Appendix B208
006, 007 WARNING: msgcnt x: mesg 006: V-2-06: vx_sumupd - mount_point file
system summary update in au aun failed
WARNING: msgcnt x: mesg 007: V-2-07: vx_sumupd - mount_point file
system summary update in inode au iaun failed
Description
An I/O error occurred while writing the allocation unit or inode allocation
unit bitmap summary to disk. This sets the VX_FULLFSCK flag on the
file system. If the VX_FULLFSCK flag can’t be set, the file system is
disabled.
Action
Check the console log for I/O errors. If the problem was caused by a disk
failure, replace the disk before the file system is mounted for write access,
and use fsck to run a full structural check.
Table B-1 (Continued)
Message
Number