Veritas File System 5.1 SP1 Administrator"s Guide (5900-1499, April 2011)

Table B-1
Kernel messages (continued)
Message and DefinitionMessage Number
WARNING: msgcnt x: mesg 063: V-2-63: vx_fset_markbad -
mount_point file system mount_point fileset (index number) marked
bad
Description
An error occurred while reading or writing a fileset structure.
VX_FULLFSCK flag is set. If the VX_FULLFSCK flag cannot be set,
the file system is disabled.
Action
Unmount the file system and use fsck to run a full structural
check.
063
WARNING: msgcnt x: mesg 064: V-2-64: vx_ivalidate - mount_point
file system inode number version number exceeds fileset's
Description
During inode validation, a discrepancy was found between the
inode version number and the fileset version number. The inode
may be marked bad, or the fileset version number may be changed,
depending on the ratio of the mismatched version numbers.
VX_FULLFSCK flag is set. If the VX_FULLFSCK flag cannot be set,
the file system is disabled.
Action
Check the console log for I/O errors. If the problem is a disk failure,
replace the disk. If the problem is not related to an I/O failure, find
out how the disk became corrupted. If no user or process is writing
to the device, report the problem to your customer support
organization. In either case, unmount the file system and use fsck
to run a full structural check.
064
NOTICE: msgcnt x: mesg 066: V-2-66: DMAPI mount event - buffer
Description
An HSM (Hierarchical Storage Management) agent responded to
a DMAPI mount event and returned a message in buffer.
Action
Consult the HSM product documentation for the appropriate
response to the message.
066
169Diagnostic messages
Kernel messages