Veritas File System 5.1 SP1 Administrator"s Guide (5900-1499, April 2011)

Table B-1
Kernel messages (continued)
Message and DefinitionMessage Number
NOTICE: msgcnt x: mesg 071: V-2-71: cleared data I/O error flag in
mount_point file system
Description
The user data I/O error flag was reset when the file system was
mounted. This message indicates that a read or write error occurred
while the file system was previously mounted.
See Message Number 038.
Action
Informational only, no action required.
071
WARNING: msgcnt x: vxfs: mesg 072: could not failover for
volume_name file system
Description
This message is specific to the cluster file system. The message
indicates a problem in a scenario where a node failure has occurred
in the cluster and the newly selected primary node encounters a
failure.
Action
Save the system logs and core dump of the node along with the
disk image (metasave) and contact your customer support
organization. The node can be rebooted to join the cluster.
072
WARNING: msgcnt x: mesg 075: V-2-75: replay fsck failed for
mount_point file system
Description
The log replay failed during a failover or while migrating the CFS
primary-ship to one of the secondary cluster nodes. The file system
was disabled.
Action
Unmount the file system from the cluster. Use fsck to run a full
structural check and mount the file system again.
075
171Diagnostic messages
Kernel messages