Veritas File System 5.1 SP1 Administrator"s Guide (5900-1499, April 2011)

V-2-20
WARNING: msgcnt x: mesg 020: V-2-20: vx_logerr - mount_point file system log
error errno
Description:
Intent log failed. The kernel will try to set the VX_FULLFSCK and VX_LOGBAD flags
in the super-block to prevent running a log replay. If the super-block cannot be
updated, the file system is disabled.
Recommended action:
Unmount the file system and use fsck to run a full structural check. Check the
console log for I/O errors. If the disk failed, replace it before remounting the file
system.
V-2-21
WARNING: msgcnt x: mesg 021: V-2-21: vx_fs_init - mount_point file system
validation failure
Description:
When a VxFS file system is mounted, the structure is read from disk. If the file
system is marked clean, the structure is correct and the first block of the intent
log is cleared.
If there is any I/O problem or the structure is inconsistent, the kernel sets the
VX_FULLFSCK flag and the mount fails.
If the error is not related to an I/O failure, this may have occurred because a user
or process has written directly to the device or used fsdb to change the file system.
Recommended action:
Check the console log for I/O errors. If the problem is a disk failure, replace the
disk. If the problem is not related to an I/O failure, find out how the disk became
corrupted. If no user or process is writing to the device, report the problem to
your customer support organization. In either case, unmount the file system and
use fsck to run a full structural check.
V-2-22
WARNING: msgcnt x: mesg 022: V-2-22: vx_mountroot - root file system remount
failed
Description:
199Diagnostic messages
Dewey kernel messages