Veritas File System 5.1 SP1 Administrator"s Guide (5900-1499, April 2011)

V-2-24
WARNING: msgcnt x: mesg 024: V-2-24: vx_cutwait - mount_point file system
current usage table update error
Description:
Update to the current usage table (CUT) failed.
For a Version 2 disk layout, the CUT contains a fileset version number and total
number of blocks used by each fileset.
The VX_FULLFSCK flag is set in the super-block. If the super-block cannot be written,
the file system is disabled.
Recommended action:
Unmount the file system and use fsck to run a full structural check.
V-2-25
WARNING: msgcnt x: mesg 025: V-2-25: vx_wsuper - mount_point file system
super-block update failed
Description:
An I/O error occurred while writing the super-block during a resize operation.
The file system is disabled.
Recommended action:
Unmount the file system and use fsck to run a full structural check. Check the
console log for I/O errors. If the problem is a disk failure, replace the disk before
the file system is mounted for write access.
V-2-26
WARNING: msgcnt x: mesg 026: V-2-26: vx_snap_copyblk - mount_point primary
file system read error
Description:
Snapshot file system error.
When the primary file system is written, copies of the original data must be written
to the snapshot file system. If a read error occurs on a primary file system during
the copy, any snapshot file system that doesn't already have a copy of the data is
out of date and must be disabled.
Recommended action:
201Diagnostic messages
Dewey kernel messages