Recommended action:
Determine which vendor supplied the registered extended attribute intervention
routine and contact their customer support organization.
V-2-63
WARNING: msgcnt x: mesg 063: V-2-63: vx_fset_markbad - mount_point file
system mount_point fileset (index number) marked bad
Description:
An error occurred while reading or writing a fileset structure. VX_FULLFSCK flag
is set. If the VX_FULLFSCK flag cannot be set, the file system is disabled.
Recommended action:
Unmount the file system and use fsck to run a full structural check.
V-2-64
WARNING: msgcnt x: mesg 064: V-2-64: vx_ivalidate - mount_point file system
inode number version number exceeds fileset's
Description:
During inode validation, a discrepancy was found between the inode version
number and the fileset version number. The inode may be marked bad, or the
fileset version number may be changed, depending on the ratio of the mismatched
version numbers.
VX_FULLFSCK flag is set. If the VX_FULLFSCK flag cannot be set, the file system is
disabled.
Recommended action:
Check the console log for I/O errors. If the problem is a disk failure, replace the
disk. If the problem is not related to an I/O failure, find out how the disk became
corrupted. If no user or process is writing to the device, report the problem to
your customer support organization. In either case, unmount the file system and
use fsck to run a full structural check.
V-2-66
NOTICE: msgcnt x: mesg 066: V-2-66: DMAPI mount event - buffer
Description:
An HSM (Hierarchical Storage Management) agent responded to a DMAPI mount
event and returned a message in buffer.
Diagnostic messages
Dewey kernel messages
210