Veritas Storage Foundation 5.1 SP1 for Oracle RAC Administrator"s Guide (5900-1512, April 2011)

The vxfenswap utility rolls back the migration operation.
If you want to commit the new fencing configuration changes, answer y
at the prompt.
Do you wish to commit this change? [y/n] (default: n) y
If the utility successfully commits, the utility moves the
/etc/vxfenmode.test file to the /etc/vxfenmode file.
7
After the migration is complete, verify the change in the fencing mode.
# vxfenadm -d
For example, after the migration from disk-based fencing to server-based
fencing in the SF Oracle RAC cluster:
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: 201
Fencing Mode: Customized
Fencing Mechanism: cps
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
8
Verify the current coordination points that the vxfen driver uses.
# vxfenconfig -l
Migrating from server-based to disk-based fencing in an online cluster
You can migrate between disk-based fencing and server-based fencing without
incurring application downtime in the SF Oracle RAC clusters.
You can migrate from server-based fencing to disk-based fencing when you want
to perform maintenance tasks on the CP server systems.
Similarly, you can migrate from disk-based fencing to server-based fencing in the
following cases:
You want to leverage the benefits of server-based fencing.
You want to replace faulty coordinator disks with CP servers.
63Overview of Veritas Storage Foundation for Oracle RAC
About preventing data corruption with I/O fencing