Veritas Volume Manager 5.0.1 Administrator's Guide, HP-UX 11i v3, First Edition, November 2009

Table 15-2
Rule attributes and default attribute values (continued)
DescriptionDefault
value
AttributeRule
Large mirror-stripe
threshold size.
Warn if a mirror-stripe
volume is larger than this.
1g (1GB)large_mirror_sizevxse_mirstripe
Large mirror-stripe number
of subdisks threshold. Warn
if a mirror-stripe volume
has more subdisks than this.
8nsd_threshold
Minimum number of
RAID-5 columns. Warn if
actual number of RAID-5
columns is less than this.
4too_narrow_raid5vxse_raid5
Maximum number of
RAID-5 columns. Warn if
the actual number of
RAID-5 columns is greater
than this.
8too_wide_raid5
No user-configurable
variables.
--vxse_raid5log1
Maximum RAID-5 log check
size. Warn if a RAID-5 log is
larger than this.
1g (1GB)r5_max_sizevxse_raid5log2
Minimum RAID-5 log check
size. Warn if a RAID-5 log is
smaller than this.
64m (64MB)r5_min_size
Large RAID-5 volume
threshold size. Warn if a
RAID-5 volume with a
non-mirrored RAID-5 log is
larger than this.
20g (20GB)large_vol_sizevxse_raid5log3
519Using Storage Expert
Identifying configuration problems using Storage Expert