Veritas Volume Manager 5.0.1 Administrator's Guide, HP-UX 11i v3, First Edition, November 2009

To set the iSCSI operational parameters on the initiator for a specific iSCSI target
Type the following command:
# vxddladm setiscsi target=tgt-id
parameter=value
Displaying details about a supported array library
# vxddladm listsupport libname=library_name.so
To display details about a supported array library
Type the following command:
# vxddladm listsupport libname=library_name.sl
Listing all supported disk arrays
Use this procedure to obtain values for the vid and pid attributes that are used
with other forms of the vxddladm command.
To list all supported disk arrays
Type the following command:
# vxddladm listsupport all
Excluding support for a disk array library
To exclude support for a disk array library
Type the following command:
# vxddladm excludearray libname=libvxenc.sl
This example excludes support for disk arrays that depends on the library
libvxenc.sl. You can also exclude support for disk arrays from a particular
vendor, as shown in this example:
# vxddladm excludearray vid=ACME pid=X1
91Administering disks
Discovering and configuring newly added disk devices