Veritas Volume Manager 5.1 SP1 Administrator"s Guide (5900-1506, April 2011)

5
Replace the HBA with a new compatible HBA of similar type in the same slot.
6
Bring the replaced HBA back into the configuration. Enter the following:
# /usr/bin/olrad -q
7
Enter the following command after you replace the HBA:
# /usr/bin/olrad -R slot_ID
8
Verify the success of the operation. The slot power should be ON, driver is
OLAR capable, and so on.
# /usr/bin/olrad -q slot_ID
9
Perform an operating system device scan to re-discover the LUNs. Enter the
following:
# ioscan -fn
10
Enable the controller in VxVM
# vxdmpadm enable ctlr=ctrl#
For example:
# vxdmpadm enable ctlr=c16
11
Verify if I/O operations are scheduled on that path. If I/O operations are
running correctly on all paths, the dynamic HBA replacement operation is
complete.
Online dynamic reconfiguration
Replacing a host bus adapter
206