Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release on BL870c i2 platform, whenever events generated by
the native indication provider is logged in the provider database, a record ID is
QXCR1001056641
associated with the logged record. To access or retrieve this record, the
getInstance method is supplied with the specific record ID. If the record ID is
not available in the provider database, the provider dumps core.
This defect is fixed in the current release. If the record ID supplied with the
getInstance method is not available in the provider database, the provider exits
gracefully without dumping core.
In the previous release on BL870c i2 platform, the directly attached storage disk
test command:
QXCR1001058688
#/opt/dasprovider/bin/Disk_Provider_test -d fails to generate events
for all subsequent directly attached storage disks available on the system if the first
instance of the disk is not supported by the
HPUXStorageNativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk tests
are enhanced to send events for all the monitored paths even if the first instance of
the disk is not supported by the
HPUXStorageNativeIndicationProviderModule.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available in
DAS Instance provider and DAS Consolidated Status provider fails for a user with
non-root privileges.
QXCR1001068706
This defect is fixed in the current release. Enumeration of classes available in DAS
Instance provider and DAS Consolidated Status provider is successful even for a
normal user.
In the previous release on BL870c i2 platform, when an internal disk is removed
from the system events are not generated by the
QXCR1001056608
HPUXStorageNativeIndicationProviderModule. Due to this, the SMH
application displays incorrect status of the removed disk as OK.
This defect is fixed in the current release. The
HPUXStorageNativeIndicationProviderModule generates indication when
an internal disk is removed from the system, as a result the SMH application displays
correct status of the removed disk.
In the previous release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the Indication
QXCR1001078598
Identifier index is reset. If the evweb current database already has events with the
same event number or Indication Identifier index, such duplicate events are not
logged in the evweb database. When events with the same event number are being
reported frequently, the events will be logged in the /var/opt/sfm/log/
event.log file and the syslog file.
In the current release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the Indication
Identifier is concatenated with a timestamp along with the event number and Index.
With this modification, the Indication Identifier can never be duplicated and all the
events generated by the provider are unique which gets logged in the evweb
database.
In the previous release, when the command evweb eventviewer is run on
BL870c i2 platform, the field Latest information on this event displays
incorrect location for the event details page.
QXCR1001083536
In the current release, when the command evweb eventviewer is run on BL870c
i2 platform, the field Latest information on this event displays correct
location http://bizsupport1.austin.hp.com/bizsupport/TechSupport/Document.jsp?
lang=en&cc=us&taskId=110&prodSeriesId=4183083&prodTypeId=18964&
prodSeriesId=4183083&objectID=c02293513 for the event details page.