HP-UX WBEM DAS Provider release notes (5900-1805, June 2011)

Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, when the evweb logviewer command is run on the new
Integrity platform, the Sense code and Information field values of the
QXCR1000992649
Native Indication provider are displayed in integer format. These values must be
displayed in Hexadecimal format.
In the current release, the Sense code and Information field values of the
Native Indication provider are displayed in Hexadecimal format when the evweb
logviewer command is run on all the platforms.
In the previous release, DAS provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
While installing the WBEMP-Storage module, version B.11.31.0903 on HP-UX
system, a temporary file /diskaldata is created and does not get deleted after
successful installation.
QXCR1000996182
In the current version of the product, the temporary file gets deleted after successful
installation of the module.
In the previous release, DAS Indication and Consolidated Status provider displays
erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, DAS Indication and Consolidated Status providers are disabled
on HP Virtual Machine guest systems.
In the previous release, the Disk exerciser tool (shipped in the product bundle) does
not work after bundle installation or upgrade. The cimserver or the
CDM-ProvidersModule has to be restarted to make the Disk exerciser tool work.
QXCR1001023857
In the current release, this defect is fixed and the Disk exerciser tool works correctly
after the bundle installation or upgradation.
In the previous release, DAS Indication provider does not display multiple IP
addresses supported for a system.
QXCR1000996827 / QXCR1001023213
In the current release, DAS Indication provider displays multiple IP addresses
supported for a system.
In the previous release, on HP-UX system, enumerate instance of HPUX
HP_DiskDrive class returns incorrect data when DAS port controllers are not
present on new Integrity servers.
QXCR1001029288
In the current release, this defect is fixed.
Defects Fixed in version B.11.31.1103
In the previous release on BL870c i2 platform, the evweb logviewer command
displays incorrect or incomplete event details for secondary storage devices. As a
result, users will be unable to locate faulty device attached to the system.
QXCR1001042481
This defect is fixed in the current release. A new field Hardware Path is added
in the evweb logviewer output. This field provides complete hardware path of
the failing hardware.
In the previous release on BL870c i2 platform, the
HPUXStorageNativeIndicationProviderModule fails to generate
esdisk/escsi related events on the platform.
QXCR1001042893
In the current release, this defect is fixed and the
HPUXStorageNativeIndicationProviderModule generate esdisk/escsi
related events on BL870c i2 platform.
In the previous release, the VirtualSystemSerialNo and SystemSerialNo
fields display incorrect value when the command evweb logviewer is run on
BL870c i2 platform.
QXCR1001051681
In the current release, these fields display approriate values when the command
evweb logviewer is run on BL870c i2 platform.
Defects Fixed in This Version 9