HP-UX WBEM LAN Provider Release Notes, September 2010

Defects Fixed in This Version
This section describes the WBEM LAN Provider defects fixed in the HP-UX 11i v2 and 11i v3
operating systems.
Table 1-4 Defect Fix in the HP-UX 11i v2 operating systems.
DescriptionDefect ID
Defect Fix in B.11.23.1003 Release
In the previous release, the LAN provider generates a core file due to an
option missing in the compilation file of LAN Consolidated Status provider
and LAN Indication provider.
This defect is fixed in the current release by including the missing option
in the compilation file of LAN Consolidated Status provider and LAN
Indication provider.
QXCR1000993165
Table 1-5 Defects Fixed in the HP-UX 11i v3 operating systems.
DescriptionDefect ID
Defect Fix in B.11.31.0909 Release
In the previous release, in certain scenarios, the LAN Indication provider
may dump core when it shuts down after generating indications.
This defect is fixed in the current release, and the LAN Indication provider
does not dump core when it shuts down after generating indications.
QXCR1000889988
Defect Fixes in B.11.31.1004 Release
In the previous release, failure messages generated by the
HPUXLANCSProviderModule are logged in /var/adm/syslog/
syslog.log file.
In the current release, these failure messages are not generated by the
HPUXLANCSProviderModule.
QXCR1000965312
In the previous release, enumerate instances method initiated for
HPUX_EthernetGroupHostedCollection class returned
CIM_ERR_FAILED, when non-root guest user executed the method using
wbemexec command.
This defect is fixed in the current release. The enumerate instances
method initiated for HPUX_EthernetGroupHostedCollection class
returns instance of the class when non-root guest user executes the method
using wbemexec command . For more information about the command,
see wbemexec(1) man page.
QXCR1000990126
In the previous release, the HPUXLANProviderModule dumps core in
certain scenarios on PA-RISC systems.
This defect is fixed in the current release.
QXCR1000985457
In the previous release, on PA-RISC systems when modify instance
method is initiated for an instance of
HPUX_LANMemberOfPolicyCollection class, the LAN Consolidated
Status provider dumps core.
This defect is fixed in the current release on PA-RISC systems.
QXCR1000991396
Defect Fixes in B.11.31.1009 Release
In the previous release, LAN Indication provider does not display multiple
IP addresses of a system.
In the current release, LAN Indication provider displays multiple IP
addresses of a system.
QXCR1001023213
10 HP-UX WBEM LAN Provider release notes