Table 8 Defects fixed in the HP-UX 11i v3 OS (continued)
In the previous release, on legacy integrity and BL870c i2 platforms, when
excessive errors are generated from a faulty component, the RAIDSAPROVDB
QXCR1001083290
database connection with the
HPUXRAIDSANativeIndicationProviderModule exceeds the threshold
limit. This potentially leads to core dump.
In the current release, the defect is fixed and excessive errors generated from
a faulty component are handled appropriately.
In the previous release, the
HPUXRAIDSANativeIndicationProviderModule is not supported on
legacy Integrity systems.
QXCR1001048147
In the current release, the
HPUXRAIDSANativeIndicationProviderModule is supported on legacy
Integrity systems. The monitors disk_em and msamon_sas no longer generate
events on legacy Integrity systems.
The consolidated status provider displays the overall status of the IO subsystem
based on the GroupOperationalStatus property severity level. The severity
QXCR1001066416
levels associated for the GroupOperationalStatus property values during
the previous release and the current release are tabulated below.
Table 9
Earlier Severity LevelCurrent Severity Level
Subsystem
GroupOperationalStatus
Has higher severity
level than the states
Has less severity level than
the states Unknown(0) and
No Contact(12).
Other(1)
Starting(8)
Unknown(0) and
No Contact(12).
Stopping(9)
In Service(11)
Dormant(15)
Power Mode(18)
Has higher severity
level than the states
Has less severity level than
the states OK(2) and
Completed(17).
Unknown(0)
No Contact(12)
OK(2) and
Completed(17).
Has the lowest
severity level.
Has the highest severity
level.
OK(2)
Completed(17)
In the previous release, cimprovagt program generated a core during unload
of the provider. The program was terminated with signal 11, segmentation
fault.
QXCR1001051369
In the current release, this problem is fixed.
Defects fixed in the B.11.31.1109 release
In the previous release, the RAIDSAProvider test binary was available in
/opt/raidsaprovider/lib directory.
QXCR1001087415
In the current release, the RAIDSAProvider test binary has been moved to
/opt/raidsaprovider/bin directory.
In the previous release, the HPUXRAIDSAIndicationProviderModule
data had junk values at the end in evweb o/p under "Error Details/Component
Data."
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS
API which fills the "Error Details/Component Data."
Defects fixed in This version 11