HP-UX WBEM SAS Provider release notes (5900-2224, March 2012 web release)

Table 7 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, the following fields were not populated with appropriate
values from the indications generated by HPUXSASIndicationProviderModule
and HPUXSASNativeIndicationProviderModule:
QXCR1001012655 / QXCR1000996830
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXSASIndicationProviderModule and
HPUXSASNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the SAS indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS
registration.
In the previous release, system log configuration file for SAS provider available at:
/opt/sas/provider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for SAS provider available at: /opt/
sas/provider/conf is termed as SASLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData
indication properties of HPUXSASIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
Defects fixed in B.11.31.1009 release
In the previous release, the HPUXSASIndicationProviderModule dumps core
when ComponentData indication properties are not retrieved successfully.
QXCR1001021614
In the current release, this defect is fixed and
HPUXSASIndicationProviderModule does not dump core.
In the previous release, SAS provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
In the previous release, SAS indication and Consolidated Status provider displays
erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, SAS indication and Consolidated Status provider is disabled
on HP Virtual Machine guest systems.
In the previous release, SAS indication provider does not display multiple IP
addresses of a system.
QXCR1000996827 / QXCR1001023213
In the current release, SAS indication provider displays multiple IP addresses of a
system.
Defects fixed in B.11.31.1103 release
In the previous release, on BL870c i2 platform, the SAS disk test command:QXCR1001058688
#/opt/sas/provider/bin/SAS_Provider_Test -d fails to generate events
for all SAS disks available on the system if the first instance of the disk is not
supported by the HPUXSASNativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk test is
enhanced to send events for all the monitored paths even if the first instance of the
disk is not supported by the HPUXSASNativeIndicationProviderModule.
In the previous release, the HPUXSASIndicationProviderModule displays
incorrect severity value after registering with EMS sub-system on HP-UX 11i v3 OS.
QXCR1001048021
Defects fixed in the version 7